OUTPUT RELAYS WORKSHEET FOR FIELDS *80, and *81.
Applicable only if relays are to be used.
Fill in required data and follow detailed programming procedure
described in PROGRAMMING DATA FIELDS section of Installation Instructions
*80 OUTPUT RELAYS
Notes:
1. Field *25 must be programmed for a 4229 (Relays 01 and 02) or a 4204 (Relays 01 to 04).
2. Tampers of contacts or expansion units cannot be used to operate relays.
S T A R T
either or both
S T O P
either or both
OUTPUT
RELAY
RELAY
ACTION
(A)
ZONE
EVENT LIST
(EV) (ZL)
ZONE TYPE
/SYST OP'N
(ZT)
"RESTORE of"
ZONE LIST
(ZL)
ZONE TYPE
/SYST OP'N
(ZT)
01
02
03
04
Where: A = RELAY ACTION 0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off
EV = EVENT 0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble
ZL = ZONE LIST 1,2, or 3 (from Field *81) or 0 = Not Used.
START ZONE LIST : Upon alarm, fault, or trouble of ANY zone on this list, relay action will START.
STOP
"RESTORE
of"
ZONE LIST: Upon restore of ALL zones on this list, relay action will STOP.
It need not be same list as used for START.
ZT = ZONE TYPE/SYSTEM OPERATION
Choices for Zone Types are:
00 = Not Used 06 = 24 Hr Silent
01 = Entry/Exit 07 = 24 Hr Audible
03 = Perimeter 08 = 24 Hr Aux
04 = Interior Follower 09 = Fire Trouble
05 = Trouble Day/Alarm Night 10 = Interior w/Delay
Note:
Any
zone in "ZT" going into alarm,
fault, or trouble will actuate relay.
Any
zone of that type that restores
will stop relay action.
Choices for System Operation are:
20 = Arming–Stay 33 = Any Burglary Alarm 39 = Any Fire Alarm
21 = Arming–Away 34 = Code + # + 7 Key Entry 40 = Bypassing
22 = Disarming (Code + OFF) 35 = Code + # + 8 Key Entry 41 = AC Power Failure
31 = End of Exit Time 36 = At Bell Timeout** 42 = System Battery Low
32 = Start of Entry Time 38 = Chime 58 = Duress
**Or at Disarming, whichever occurs earlier.
*81 ZONE LISTS FOR OUTPUT RELAYS Record desired zone numbers. More or fewer boxes than shown may be
needed, since any list may include
any
or
all
of system's zone numbers.
Zone List 1: Started or stopped by zone numbers (enter 00 to end entries).
, , , , , , , , , ...etc.
Zone List 2: Started or stopped by zone numbers (enter 00 to end entries).
, , , , , , , , , ...etc.
Zone List 3: Started or stopped by zone numbers (enter 00 to end entries).
, , , , , , , , , ...etc.